text.skipToContent text.skipToNavigation

EPA Methods 200.7, 6010 and 6010A Standards for ICP AES

200.7 Rev. 4.4 - Calibration Standard 1: Ag @ 50; B, Ba, Be, Cd, Ce, Co, Cr, Cu, Mn, Ni, Pb, Sr, V @ 200; As, Se, Tl, Zn @ 500; Ca, K, Mg, P @ 1000 µg/mL in 5% HNO3 100 mL VHG-44CS1Y-100
200.7 Rev. 4.4 - Calibration Standard 1: Ag @ 50; B, Ba, Be, Cd, Ce, Co, Cr, Cu, Mn, Ni, Pb, Sr, V @ 200; As, Se, Tl, Zn @ 500; Ca, K, Mg, P @ 1000 µg/mL in 5% HNO3 500 mL VHG-44CS1Y-500
200.7 Rev. 4.4 - Calibration Standard 2: Sn @ 200; Li, Sb @ 500; Al, Fe, Mo, Na, SiO2, Ti @ 1000 µg/mL in 20% HCl, tr. HF 100 mL VHG-44CS2Z-100
200.7 Rev. 4.4 - Calibration Standard 2: Sn @ 200; Li, Sb @ 500; Al, Fe, Mo, Na, SiO2, Ti @ 1000 µg/mL in 20% HCl, tr. HF 500 mL VHG-44CS2Z-500
200.7, 6010 - Quality Control (QCS) Solution 1: Ag @ 50; As, B, Ba, Be, Ca, Cd, Ce, Co, Cr, Cu, Hg, Mg, Mn, Ni, P, Pb, Se, Sr, Tl, V, Zn @ 100 µg/mL in 5% HNO3 100 mL VHG-44QCS1Z-100
200.7, 6010 - Quality Control (QCS) Solution 1: Ag @ 50; As, B, Ba, Be, Ca, Cd, Ce, Co, Cr, Cu, Hg, Mg, Mn, Ni, P, Pb, Se, Sr, Tl, V, Zn @ 100 µg/mL in 5% HNO3 500 mL VHG-44QCS1Z-500
200.7, 6010 - Quality Control (QCS) Solution 2: Al, Fe, K, Li, Mo, Na, Sb, SiO2, Sn, Ti @ 100 µg/mL in 20% HCl, tr. HF 100 mL VHG-44QCS2Z-100
200.7, 6010 - Quality Control (QCS) Solution 2: Al, Fe, K, Li, Mo, Na, Sb, SiO2, Sn, Ti @ 100 µg/mL in 20% HCl, tr. HF 500 mL VHG-44QCS2Z-500
200.7, 6010 - Interference Check Solution 1: Hg @ 50; Be @ 100; Mn @ 200; Ag, Ba, Cd, Co, Cr, Cu, Ni, V, Zn @ 300; Se @ 500; As, Pb, Tl @ 1000; K @ 20000 µg/mL in 5% HNO3 100 mL VHG-INT1-100
200.7, 6010 - Interference Check Solution 1: Hg @ 50; Be @ 100; Mn @ 200; Ag, Ba, Cd, Co, Cr, Cu, Ni, V, Zn @ 300; Se @ 500; As, Pb, Tl @ 1000; K @ 20000 µg/mL in 5% HNO3 500 mL VHG-INT1-500
200.7, 6010 - Interference Check Solution 2: Si @ 230; Mo @ 300; B @ 500; Ti @ 1000 µg/mL in 2% HNO3, tr. HF 100 mL VHG-INT2-100
200.7, 6010 - Interference Check Solution 2: Si @ 230; Mo @ 300; B @ 500; Ti @ 1000 µg/mL in 2% HNO3, tr. HF 500 mL VHG-INT2-500
200.7, 6010 - Interference Check Solution 3: Sb @ 1000 µg/mL in H2O, Tartaric Acid, tr. HNO3 100 mL VHG-INT3-100
200.7, 6010 - Interference Check Solution 3: Sb @ 1000 µg/mL in H2O, Tartaric Acid, tr. HNO3 500 mL VHG-INT3-500
200.7, 6010 - Interference Check Solution 4: Na @ 1000; Al @ 1200; Mg @ 3000; Fe @ 5000; Ca @ 6000 µg/mL in 5% HNO3 100 mL VHG-INT4-100
200.7, 6010 - Interference Check Solution 4: Na @ 1000; Al @ 1200; Mg @ 3000; Fe @ 5000; Ca @ 6000 µg/mL in 5% HNO3 500 mL VHG-INT4-500
200.7, 6010 - Instrument Performance Check (IPC) Solution 1: Ag @ 20; As, B, Ba, Be, Ca, Cd, Ce, Co, Cr, Cu, Mg, Mn, Ni, Pb, Se, Sr, Tl, V, Zn @ 100; K, P @ 500 µg/mL in 5% HNO3 100 mL VHG-IPC1Y-100
200.7, 6010 - Instrument Performance Check (IPC) Solution 1: Ag @ 20; As, B, Ba, Be, Ca, Cd, Ce, Co, Cr, Cu, Mg, Mn, Ni, Pb, Se, Sr, Tl, V, Zn @ 100; K, P @ 500 µg/mL in 5% HNO3 500 mL VHG-IPC1Y-500
200.7, 6010 - Instrument Performance Check (IPC) Solution 2: Al, Fe, Hg, Li, Mo, Na, Sb, Sn, Ti @ 100; SiO2 @ 500 µg/mL in 20% HCl, tr. HF 100 mL VHG-IPC2Y-100
200.7, 6010 - Instrument Performance Check (IPC) Solution 2: Al, Fe, Hg, Li, Mo, Na, Sb, Sn, Ti @ 100; SiO2 @ 500 µg/mL in 20% HCl, tr. HF 500 mL VHG-IPC2Y-500